Rotating Anode Tube for 150KV High Speed X Ray Film Machine CR DR System XD90 Equivalent to IAE X50 Nago Gd6

Rotating Anode Tube for 150KV High Speed X Ray Film Machine CR DR System XD90 Equivalent to IAE X50 Nago Gd6

Quick Detail: Type: Rotating anode x-ray tube Application: For Medical diagnosis x-ray unit Model: XD90-1.0/2.0-150 Integrated high quality glass tube Description: XD90-1.0/2.0-150 tube has a double focus designed for use with standard-speed anode rotation for high energy radiographic and...

Product Details

Rotating Anode Tube for 150KV High Speed X Ray Film Machine CR DR System XD90 Equivalent to IAE X50 Nago Gd6


Quick Detail:

Type: Rotating anode x-ray tube

Application: For Medical diagnosis x-ray unit

Model: XD90-1.0/2.0-150

Integrated high quality glass tube


Description:

XD90-1.0/2.0-150 tube has a double focus designed for use with standard-speed anode rotation for high energy radiographic and cine-fluoroscopic operations.

The integrated high quality tube with glass design has two super imposed focal spots and a rein-forced 90 mm anode. The high anode heat storage capacity ensures a wide range of applications for standard diagnostic procedures with conventional radiographic and fluoroscopy systems.

A special designed anode enables an elevated heat dissipation rate which leads to a higher patient through- put and a longer product life.

A constant high dose yield during the entire tube life is ensured by the high density rhenium-tungsten compound target. Ease of integration into system products is facilitated by extensive technical support.


OUTLINE DRAWING:


a.jpg

5847.jpg



Applications:

XD90-1.0/2.0-150 rotating anode X-Ray Tube is especially designed for Medical diagnosis x-ray unit.


Specifications:

Maximum Operating Voltage....................................................................150KV

Focal Spot Size........................................................................................1.0/2.0

Diameter....................................................................................................90mm

Target Material............................................................................................ RTM

Anode Angle................................................................................................16°

Rotation Speed....................................................................................2800RPM

Heat Storage..........................................................................................190kHU

Maximum Continuous Dissipation.............................................................490W

Filament Characteristics

Small filament..............................................................fmax=5.4A ,Uf=8.0±1V

Big filament ..............................................................Ifmax=5.4A,Uf=11.0±1V

Inherent Filtration....................................................................................1mmAL

Maximum Power...…..................................................................30KW/50KW


Competitive Advantage:

Standard speed anode rotation with silenced bearings

High density compound anode (RTM)

Elevated anode heat storage capacity and cooling

Constant high dose yield

Excellent lifetime

 